The Do's and Don'ts of Tying Rebar

Author: Janey

Jun. 10, 2024

The Do's and Don'ts of Tying Rebar

At a glance, the process of tying rebar may look easy. However, the reality is that is it quite a lengthy and complicated process. While it isn&#;t exactly rocket science, there are still a lot of things one needs to take into consideration when tying rebar. Do it improperly, and you risk endangering the entire integrity of a structure. In this short guide, we highlight the dos and don&#;ts of tying rebar.

The company is the world’s best snap tie layout supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

The Dos

Do Your Homework

Do your homework on what sizes, configuration, and placement of rebar will be required, as well as what type of chairs would be best for the job. Both concrete and plastic chairs have their pros and cons, and it will depend on your situation and budget in deciding which one to use. Additionally, you will have to consider how you will tie your rebar. Annealed steel wires are cheaper and more versatile while bag tie spinners are easier to work with but can cost more.

Do Share Building Plans with the Supplier

Everything from rebar placements to the use of chairs in rebar support needs to be precise. Therefore, it is important to share your building plans in detail with rebar and rebar support suppliers. This will allow them to supply you with the right rebar sizes and rebar support, and in the right amount.

Do Mark the Layout Bars

Placing and keeping the bars in the right position is essential to achieving the desired strength of the completed concrete structure. To aid in this regard, use the layout bars as your reference. Make sure to mark them properly so you can differentiate them easily.

Do Use the Appropriate Type of Tie

For ordinary construction projects where the force of the concrete on rebar during its placement would be minimal, a simple snap tie would suffice in tying the rebar together. However, for other cases where the force of the concrete placement risks displacing the rebar, more advanced methods of ties are needed. The two most common types of advance rebar tie methods are Figure 8 and the Saddle.

For holding perpendicular bars firmly together and reducing the risk of racking, figure 8 is used. Meanwhile, for tying rebar for walls or other vertical constructions, the Saddle tie is used. In real-world applications, a combination of both along with other tie methods will be used depending on the nature and requirements of the rebar construction.

Do Chair Your Rebar

Chairs are extremely important in helping keep the rebar in their correct positions during construction. Once the mat has been established, the chairs will hold the rebar in place as the concrete covers it completely.

The Don&#;ts

Don&#;t Be Negligent of Rebar Configuration While the Concrete Is Placed

As the concrete is poured over the rebar, shifting can occur, putting the rebar out of alignment. To remedy this, you can support the rebar with a handled tool such as a shovel wedge to give sufficient leverage to allow it to hold its position. Alternatively, you may alter the direction of flowing concrete, so the force is applied in the opposite direction.

Don&#;t Forget to Put Caps on Any Exposed Rebar

Unless you want to risk serious injuries, always make sure to put caps on exposed rebar. The cut ends of rebar are extremely sharp, and in the past, some construction works have even been maimed or killed by falling over projecting rebar dowels. As required by the Occupational Safety and Health Administration (OSHA), special rods cap made with high resistance plastic should be placed on any exposed rebar cut ends.

Don&#;t Place Rebar Support Too Far Apart

Rebar support has to be placed at just the right distance between them. If they are too far apart, the rebar will bend in the middle due to its weight and thus, result in more headaches for you. Another rebar support problem that may arise is that the rebar chairs, especially plastic ones, can also break due to the excessive weight put on them. Cracks can also form on concrete blocks, compromising the robustness of the structure being built.

Don&#;t Use the Wrong Chair

As mentioned before, different types of chairs have their own advantages and disadvantages. If the rebar structure is not too weighty, and the end structure won&#;t be subject to too much abuse from the elements, plastic chairs would be a decent, affordable option. Meanwhile, concrete blocks augment the strength and durability of the whole structure, but it would be an overkill to use them in a small scale, not too demanding, construction project.

Don&#;t Try to Arc Weld Rebar

To achieve proper adhesion, the welding process must be able to heat the surface of the metal rebar to the melting point, which is difficult to do on most rebar types. Only certain types of rebar with a &#;W&#; stamped on it can be welded. Even then, you must be a qualified welder and have a procedure planned to weld them.

To achieve the optimal results and avoid running into any problems, consider applying the best practices when it comes to tying rebar and rebar construction. If you found the information in this article useful, do consider sharing it with your colleagues and friends.

ICF Insulated Concrete Forms Problems & Leaks


ICF Insulated Concrete Form Problems

Pros and Cons of ICF Forms The Good * The Bad * AND the Ugly!

This article states facts not to criticize or endorse ICF Insulated Concrete Forms. The results of many years of experience dealing with foundation flaws and cracking problems with this type of construction in below-grade basements. Usually, long after, the builder no longer takes any responsibility for their work.

Insulated concrete forms (ICF) have become popular today for many home builders because concrete professionals or contractors are not needed. Typically, the carpenter, home builder, or homeowner on-site can assemble the forms without any outside help.

What is an ICF form?

In its simplest form, ICF Forms are two rigid polyurethane or polystyrene foam sheets separated with plastic separators. These separators set the wall thickness and are placeholders for rebar reinforcement. However, form-work problems can occur, translating into possible leaking issues. At NextStar, we have seen many problems with ICF Form basements. We find that most home builders are unaware or in denial of any of these problems.


ICF Insulated Concrete Forms Pros and Cons 

Advantages of ICF construction:

  • Can be assembled without skilled labor.
  • Provides ready-to-go foundation wall insulation on both sides.
  • Can give a continuous foundation for above-grade construction.
  • It provides an internal structure to hold rebar and, in most cases, more rebar than used in traditional foundation construction.
  • ICF Forms can be easily modified for plan changes such as windows and doors.
  • There are probably more advantages, but for this article, some are duplicates of standard concrete construction.

Disadvantages of ICF construction:

  • ICF construction foundations usually cost more than the standard wood form and pour.
  • ICF forms require extra support during setup to ensure the forms remain in place before and after pumping the concrete into the ICF forms. This additional cost needs to be factored into the overall cost. Often not done.
  • Selecting the correct concrete slump and aggregate size requires more care to ensure it meets the ICF Form manufacturer&#;s specifications.
  • During the concrete pour, the concrete mix tends to stick to the foam, preventing it from flowing, especially in the cold.
  • It requires a membrane outside because the (snap ties) plastic separators have a wick effect, explained later.
  • The thermal mass advantage may be questionable since both sides of the foundation are insulated. In addition, some reports indicate higher energy efficiency during colder months but less energy efficiency during the warmer months. Therefore, geographical location is essential in determining an ICF foundation's actual energy efficiency results.
  • The plastic separators (snap ties) cause many more penetrations through the concrete, which provides more opportunities for water to penetrate. This higher volume of penetration spots may weaken the overall concrete wall over time.
  • Diagnosing ICF foundation issues is more difficult for foundation repair professionals.

 

ICF Insulated Concrete Form Problems

Wicking problem?

ICF forms have some polypropylene separators (snap ties) to hold the two sides of the form together. The smooth finish of these materials can allow water to wick inside the concrete and seep inside the foundation. The ICF forms have gaps between the blocks that enable direct water access to the concrete.

Membrane Installed?

When inspecting a problem foundation, the first thing we look for is to verify if a membrane has been installed. With a membrane appropriately installed, there should never be a leak. If Leaking, the membrane has been damaged or not installed high enough before backfilling, allowing water to get past it.

This is important because leaks are so hard to detect. Standard crack injection methods on these foundations are comparable to the whack-a-mole game. Once one leak is injected and fixed, two more areas will start leaking shortly afterward.

Building Codes

In most areas of North America, the building code now requires that ICF foundation basements have proper membranes installed. Sometimes, dimple panels also direct water to a weeping tile drain system. However, we continue to see newly built ICF foundations with no membrane or some tar roll-on coating that is not adequate&#;in some cases, backfilled before an inspection by the building inspector.

ICF Differences

Standard concrete basement wood forms have metal snap ties every 16-24 inches horizontally and 24 inches vertically. In an ICF foundation, every block form may have 4 to 5 times more separators through the concrete to the exterior. Metal snap ties bond well with concrete, but smooth-finished plastic separators bond poorly against concrete. These will eventually allow water and moisture to wick or penetrate the foundation.

Are you interested in learning more about pvc plywood? Contact us today to secure an expert consultation!

Featured content:
The Complete Low Volume Injection Molding Guide - Prototool
Maximize Efficiency: Benefits of Low Pressure Overmolding
The Ultimate Guide to Hydraulic Chuck Tool Holders
Is the Ball Gate Valve the Key to Unlocking Sustainable Energy?
What are the benefits of using Ruihan's Standard Er Collet?
Machine Collet 101: How To Choose The Right Collet
How do you choose the best Tool Holder Collets Market products?

When a crack is identified, the excess foam must be removed before applying standard crack injection techniques. The IC foam makes it more difficult to determine where the leaks are located, requiring more labor time. Usually, we find that a crack originated from a plastic snap tie. It develops when the concrete shrinks during the curing process.

We always caution homeowners that crack injection in an ICF foundation only fixes a symptom of the real problem. That is the absence of a proper membrane. Some foundations are so bad that they require excavation, a proper membrane, and new weeping tile. A cracked or faulty poured foundation can be repaired with polyurethane or epoxy injection. This isn't a long-term solution for an ICF foundation. Fixing one location only chases the water to the next snap tie or flaw.

An ICF foundation that has been installed correctly should have no issues. If any problems occur, the Insulation foam hides flaws, and homeowners do not discover the problem until long after the structure is completed.

Workmanship problems:

  • They do not properly support the forms when the concrete is poured, often because they are in a rush or to save costs. They avoid using a vibrator or tamping to prevent blowouts, leaving many areas of the foundation with honeycombed voids. This is a significant problem with many foundations we see, and in some cases, the voids are so bad that groundwater easily runs through.
  • Common large voids left under a window or door sill plates. Wood forms around the openings installed without leaving the bottom sill plate open for concrete to be pumped into. This can leave large voids in these areas. The best option to repair this is to remove the foam. Apply grout made of Epoxy and Sand to structurally bond and fill the void space.

  • Many builders use the wrong aggregate size and slump recommended by the ICF form manufacturer, contributing to many problems.

 

Our Recommendations to Avoid Problems

To avoid problems, if you decide to build with insulated concrete forms, hire experienced installers who have installed standard concrete forms. Ensure the forms are well-supported and plumb and the concrete is vibrated. Even if it costs more to reinforce the forms, the quality of the foundation will pay for itself.

If one of your considerations was whether thermal mass would heat or cool, you may want to consider a standard foundation and only foam insulation for the exterior instead. This will allow the foundation's temperature to match the structure's interior temperature.

Are you installing ICF? Then, install an external membrane and secure it above grade. If possible, install a secondary membrane directed to the weeping tile. Do this correctly. You should never need help from a foundation repair contractor. Pay and do it right the first time, or with an ICF Foundation, pay dearly later.

What do I Do if you have a Leaky ICF Foundation?

Things to check first:

1. Is water draining close to the exterior wall? If so, direct it away.

2. If your foundation has a sump pump, ensure it operates and pumps away from the foundation.

3. The soil against the foundation is sloped away from the walls.

4. Dig in a soil area next to the basement wall 6-10 inches deep. Determine if the wall has a membrane or if the ICF Foam is exposed to the soil. If no membrane is found, this is a severe deficiency, you may need to contact a local foundation contractor to examine the problem.

5. Remove any drywall and inspect if you have a wet spot along the basement wall. Usually, it will show dark watermarks on the ICF foam.

6. Removing foam to inspect the wall may be required to identify the problem.

Problems and Solutions for your ICF Home

Cracks - Standard Polyurethane low or High-Pressure method.

Holes - Standard Polyurethane or Epoxy Injection.

Voids - Epoxy grout mixture to fill the void area.

Porous walls, holes, and voids are everywhere. Excavate and Install or repair an external membrane

Credits © NextStar Technologies Authors C Groner, N Wathen, L Frey

 

Company Contact info


NextStar Technologies

Suite #103 112 Ave
Grande Prairie Alberta Canada T8V 7T2
USA/Canada Toll Free
866-445- 
Contact-Page

Fax  780-800-

Sites WWW.NextStar.ca   www.NextStartech.com

 

Want more information on plywood plastic? Feel free to contact us.

Featured content:
Key Questions to Ask When Ordering Ruihan's R8 End Mill Holder Set
Brass Twisted Wire Bore Brushes
How to Choose Best Keyless Drill Chuck? The Ultimate Guide
How to choose vibrating screen mesh services?
Everything You Need to Know About Collet Sk: FAQs Answered
What are the Best Vibrating Screen Mesh Solutions?
Revolutionize Your Screen Experience with Custom Mesh: TIPS?

80

0

Comments

0/2000

All Comments (0)

Related Articles

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name: (required)

Your Email: (required)

Subject:

Your Message: (required)

0/2000