What is the use of the PC strand? | by Yangbruce
Jul. 29, 2024
What is the use of the PC strand? | by Yangbruce
What is the use of the PC strand?
If you are looking for more details, kindly visit HUAYONGXIN.
Yangbruce
·
Follow
2 min read
·
Jan 10,
--
In this article, I, as a manufacturer of PC strands, explain what is the use of PC strands.
PC strand, or prestressed concrete strand, is a high-strength steel wire used to reinforce concrete structures. It is made by cold drawing high-strength steel wire into strands, which are then heated and stretched to prestress the strand. PC strand is used in a variety of concrete construction applications including bridges, buildings, car parks, and other types of infrastructure.
One of the main benefits of using the PC strand is that it allows concrete structures to be designed with longer spans and smaller cross-sections, thus using less material and making the construction of the structure more economical.PC strand also has a high tensile strength, which means that it can withstand large amounts of stress without breaking. This makes it an ideal reinforcement material for concrete structures subjected to heavy loads, such as bridges and multi-story buildings.
In addition to its tensile strength, the PC strand has good corrosion resistance, which means it retains its strength and integrity even in harsh environments. This makes it a suitable reinforcement material for use in marine environments and highly polluted areas.
PC strand is often used in conjunction with other reinforcement materials such as rebar to provide additional strength and support to concrete structures. It is also used with prestressed concrete beams, which are prestressed using PC strands before being placed into the structure. This allows the beam to carry heavy loads without cracking or deforming.
PC strand is available in a range of sizes and strengths and is usually supplied in reels or spools for ease of handling and installation. It is commonly installed in concrete structures using one of several methods, including stressed tendons, post-tensioning, and pre-tensioning.
Want more information on Prestressed Concrete Steel Wire? Feel free to contact us.
Overall, the PC strand is an important reinforcement material that is widely used in the construction of concrete structures. It enables designers to create more efficient and economical structures that can withstand heavy loads and maintain their integrity in harsh environments. If you have a requirement, you can contact us!
High Tensile Prestressed Steel Strand / PC Wire / PC Strand ...
General Intro
Prestressed Steel Strand is an engineered steel PC wire with multi-sides profiles, special for reinforcement of prestressed concrete structure.
PC steel strand is the simplified term describing Prestressed Concrete Steel Strand Wire. With the advantages of high tensile strength and good corrosion resistance at elevated temperature, PC strand wire is used in heavy loading concrete constructions. It is made with galvanized steel wire or carbon steel wire through drawing, twisting or stranding and stabilizing. The stranded wire structures allow high tension and less distortion in uses.
Common sizes: 9.3 mm. 9.6.12.7, 12.5, 12.9, 11.11, 11.3, 15.24 and 15.7 mm.
Raw Materials: High-carbon steel wire rods, SWRH 82B
Processing: Continuous drawing by means of big reduction of area, twist, stabilizing treatment
Features: High tensile strength, low relaxation, stable modulus of elasticity, stress-relieved, firm connection with concrete, low stress, stable construction, good combination with steel reinforced concrete; saving material, reducing distortion and construction weight, increasing the abrasion resistance, water resistance, stiffness.
Standards We Follow: Concreate PC Strand confirms to the technical standards such as GB/T , GB/T , ASTM A-416, BS , JIS G or the standards agreed by both of the customers and us.
Prestressed steel concrete strand or PC strand can also be supplied in various forms for pre- or post-tensioning applications, with plain or galvanized material ranging from 3 wires, 7 wires, 19 wire and compacted construction.
Packing: Export anti-rust packing with vapors corrosion inhibiting technology and 3 coatings. There are two wooden pallets on the bottom.
Application
Our PC strand is mainly used for the reinforcement of prestressed concrete structures, such as large-span railway and road bridges, major bridges, silos, buildings, dams, floor slabs, foundations, large concrete vessels, atomic reactor buildings, stadiums, airport hangers, pre-cast segments, crane beams, anchorages and multi-storey industrial buildings etc.
Our PC strand is also used for the construction of highways, poles and water towers in civil construction, and energy source sea transportation, house buildings, water control projects, and rock and earth anchoring components to increase the tensile force.
1×2 Structure strand size and tolerance, reference quality per meter
Strand Structure Nominal Diameter Strand Diameter Tolerance/mm Strand reference sectional area
Sn/mm2 Strand reference quality per meter
/(g/m) Strand Diameter
Dn/mm Wire Diameter
d/mm 1×2 5.00 2.50 +0.15
-0.05 9.82 77.1 5.80 2.90 13.2 104 8.00 4.00 +0.25
-0.10 25.1 197 10.00 5.00 39.3 309 12.00 6.00 56.5 444
1×3 Structure strand size and tolerance, reference quality per meter
Strand Structure Nominal Diameter Strand MeasurementA/mm Measurement A Tolerance
/mm Strand reference sectional area
Sn/mm2 Strand reference quality per meter
/(g/m) Strand Diameter
Dn/mm Wire Diameter
d/mm 1×3 6.20 2.90 5.41 +0.15
-0.05 19.8 155 6.50 3.00 5.60 21.2 166 8.60 4.00 7.46 +0.20
-0.10 37.7 296 8.74 4.05 7.56 38.6 303 10.80 5.00 9.33 58.9 462 1×3 I 12.90 6.00 11.20 84.8 666 8.74 4.05 7.56 38.6 303
1×7 Structure strand size and tolerance, reference quality per meter
Strand Structure Nominal DiameterDn/mm Diameter Tolerance
/mm Strand reference sectional area
Sn/mm2 Strand reference quality per meter/(g/m) Center wire diameter (do) enlarged range/% not less than 1×7 9.50 +0.30
-0.15 54.8 430 2.5 11.10 74.2 582 12.70 +0.40
-0.20 98.7 775 15.20 140 15.70 150 17.80 191 1×7C 12.70 +0.40
-0.20 112 890 15.20 165 18.00 223
1×2 Mechanical properties of structural steel strand
Strand Structure Strand nominal diameterDn/mm Abstract tensile strength Rm/Mpa not less than The largest force of the whole strand Fm/kN not less than Rated non-proportional extension force Total extension ratio at the largest force (Lo400)Agt/% not less than Stress Relaxation Initial load equivalent to the percentage of the nominal largest force/% After h stress relaxation rate r/% not less than 1×2 5.00 15.4 13.9 3.5 60
70
80 1.0
2.5
4.5 16.9 15.2 18.3 16.5 19.2 17.3 5.80 20.7 18.6 22.7 20.4 24.6 22.1 25.9 23.3 8.00 36.9 33.2 39.4 35.5 43.2 38.9 46.7 42.0 49.2 44.3 10.0 57.8 52.0 61.7 55.5 67.6 60.8 73.1 65.8 77.0 69.3 12.00 83.1 74.8 88.7 79.8 97.2 87.5 105 94.5 Note: Rated non-proportional extension force Fp0.2 is not less than 90% of the largest force of the whole strand
1×3 Mechanical properties of structural steel strand
Strand Structure Strand nominal diameterDn/mm Abstract tensile strength Rm/Mpa not less than The largest force of the whole strand Fm/kN not less than Rated non-proportional extension force Total extension ratio at the largest force (Lo400)Agt/% not less than Stress Relaxation Initial load equivalent to the percentage of the nominal largest force/% After h stress relaxation rate r/% not less than 1×3 6.20 31.1 28.0 3.5 60
70
80 1.0
2.5
4.5 34.1 30.7 36.8 33.1 38.8 34.9 6.50 33.3 30.0 36.5 32.9 39.4 35.5 41.6 37.4 8.60 55.4 49.9 59.2 53.3 64.8 58.3 70.1 63.1 73.9 66.5 8.74 60.6 54.5 64.5 58.1 71.8 64.6 10.80 86.6 77.9 92.5 83.3 101 90.9 110 99.0 115 104 12.90 125 113 133 120 146 131 158 142 166 149 8.74 60.6 54.5 64.5 58.1 71.8 64.6 Note: Rated non-proportional extension force Fp0.2 is not less than 90% of the largest force of the whole strand
1×7 Mechanical properties of structural steel strand
Strand Structure Strand nominal diameterDn/mm Abstract tensile strength Rm/Mpa not less than The largest force of the whole strand Fm/KN not less than Rated non-proportional extension force Total extension ratio at the largest force (Lo400)Agt/% not less than Stress Relaxation Initial load equivalent to the percentage of the nominal largest force/% After h stress relaxation rate r/% not less than 1×7 9.50 94.3 84.9 3.5 1.02.54.5 102 91.8 107 96.3 11.10 128 115 138 124 145 131 12.70 170 153 184 166 193 174 15.20 206 185 220 198 234 211 241 217 260 234 274 247 15.70 266 239 279 251 17.80 327 294 353 318 (1×7)C 12.70 208 187 15.20 300 270 18.00 384 346 Note: Rated non-proportional extension force Fp0.2 is not less than 90% of the largest force of the whole strand
The standard of PC steel wire:
1.GB/T -
2.ASTM A648
3.BS -
4.ASTM A421
Need more information about Concreate Reinforcing Products? Contact us now.
52
0
0
All Comments (0)
Previous: 5mm PSB555/700 Thread Bar Chinese?
Next: Improving Construction: The Benefits of 28mm Hot Rolled Thread Bars
If you are interested in sending in a Guest Blogger Submission,welcome to write for us!
Comments