Plumbing question: Gate valve - Reef2Reef
Oct. 07, 2024
Plumbing question: Gate valve - Reef2Reef
Im curious to know where the best place to install a gate valve is, if there is one. My drain pipe comes down from the tank, hits 90degrees to go toward the front of the tank, then another 90degrees to go down into a clarisea. Im sure the best place to install the gate valve is on the last piece of pipe that goes straight down into the clarisea, but would it make a difference if it is installed on the first pipe that comes down from the tank before it makes the turns? I imagine it might still make noise if I choose that way because the water is moving so much as opposed to going straight down. Or what about on the horizontal pipe between the two 90degrees?
Gate Valve installation - Pipelines, Piping and Fluid ...
INTELLIGENT WORK FORUMS
FOR ENGINEERING PROFESSIONALS
Log In
Come Join Us!
Are you an
Engineering professional?
Join Eng-Tips Forums!
- Talk With Other Members
- Be Notified Of Responses
To Your Posts - Keyword Search
- One-Click Access To Your
Favorite Forums - Automated Signatures
On Your Posts - Best Of All, It's Free!
*Eng-Tips's functionality depends on members receiving . By joining you are opting in to receive .
Posting Guidelines
Students Click Here
Promoting, selling, recruiting, coursework and thesis posting is forbidden.
Eng-Tips Posting PoliciesContact US
Gate Valve installation
thread378- Forum Search FAQs Links MVPs-
Forum
-
Search
-
FAQs
-
Links
-
MVPs
Gate Valve installation
Gate Valve installation
teddyboy(Petroleum)
(OP)
1 Dec 08 03:07Hi everyone, Could somebody give me a tip regarding the gate valves on horizontal line with its handwheel at horizontal position. If this arrange will not be of any problem in the future? The applications are for steam and liquid hydrocarbons.
Replies continue below
Recommended for you
RE: Gate Valve installation
pennpiper(Mechanical)
1 Dec 08 07:10I think you mean "The stem" in the horizontal position, right?
If so then let's look at this in a logical manner.
What if we had a Gate Valve in a vertical line? The Stem would be in the horizontal position would it not?
So if a valve stem in the horizontal position is alright for a vertical line why would a valve stem in the horizontal not be alright for a horizontal line?
RE: Gate Valve installation
BigInch(Petroleum)
1 Dec 08 07:45The handwheel might be buried 4 feet underground.
Featured content:Universal Flange Adaptor: Your Questions Answered!
The Advantages of Installing Adjustable Shower Heads
solid Product Page
**********************
"Pumping systems account for nearly 20% of the world's energy used by electric motors and 25% to 50% of the total electrical energy usage in certain industrial facilities." - DOE statistic (Note: Make that 99.99% for pipeline companies) http://virtualpipeline.spaces.live.com/
RE: Gate Valve installation
insult2injury(Mechanical)
1 Dec 08 08:49Advise the vendor of the orientation. Often they will hardface the sliding the contact faces of the guides; otherwise, it's the same valve.
I2I
RE: Gate Valve installation
JJPellin(Mechanical)
1 Dec 08 21:38In the past couple of years, we have seen a growing problem with broken stems on gate valve. I think the quality of valves coming from some countries is less than it had been in the past. With the stem in the vertical, a broken stem can result in a valve failing closed. With the stem in the horizontal, the valve would tend to fail in place if the stem breaks. You should consider the consequences of these possible failure modes. In some services, a valve that failed closed unexpectedly could cause disaster. If this is the case, I prefer a horizontal stem orientation. Otherwise, it's just a mater of convenience and operator access.
Johnny Pellin
RE: Gate Valve installation
BigInch(Petroleum)
1 Dec 08 22:29Interesting point, but I think, if it is truely a 50/50 position thing w/o actuator, I'd rather have a valve fail closed. At least you know you've got a problem then if you run out there during some kind of emergency and try to close it only to find out you can't.
**********************
"Pumping systems account for nearly 20% of the world's energy used by electric motors and 25% to 50% of the total electrical energy usage in certain industrial facilities." - DOE statistic (Note: Make that 99.99% for pipeline companies) http://virtualpipeline.spaces.live.com/
RE: Gate Valve installation
KenA(Chemical)
2 Dec 08 02:39BigInch - just so long as that gate valve isn't in the inlet to a PSV!
RE: Gate Valve installation
BigInch(Petroleum)
2 Dec 08 03:58That wouldn't be one of those 50/50 situations.
Da.That wouldn't be one of those 50/50 situations.
**********************
"Pumping systems account for nearly 20% of the world's energy used by electric motors and 25% to 50% of the total electrical energy usage in certain industrial facilities." - DOE statistic (Note: Make that 99.99% for pipeline companies) http://virtualpipeline.spaces.live.com/
RE: Gate Valve installation
gmax137(Nuclear)
2 Dec 08 20:23Are you guys allowed to put gate valves at the inlet to safety valves?? Or, does "PSV" mean something else?
RE: Gate Valve installation
Zapster(Electrical)
2 Dec 08 20:31gmax137, YES unless the latest edition of the BPV code has changed.
RE: Gate Valve installation
Zapster(Electrical)
3 Dec 08 01:58I had to take a look at the BPV VIII Div 1 just to remember all of the nuances required for a stop valve. The current version of the code is . I only have at my office and I have inserted the dialog from the version below. The goes into greater depth about the limitations; however they are still allowed. As I stated above, I am unsure about the appendix.
M-5 STOP VALVES BETWEEN PRESSURE RELIEVING DEVICE AND VESSEL
(a) A vessel, in which pressure can be generated because of service conditions, may have a full-area stop valve between it and its pressure relieving device for inspection and repair purposes only. When such a stop valve is provided, it shall be so arranged that it can be locked or sealed open, and it shall not be closed except by an authorized person who shall remain stationed there during that period of the vessel's operation within which the valve remains closed, and who shall again lock or seal the stop valve in the open position before leaving the station.
Red Flag This Post
Please let us know here why this post is inappropriate. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework.
Red Flag Submitted
Thank you for helping keep Eng-Tips Forums free from inappropriate posts.
The Eng-Tips staff will check this out and take appropriate action.
Reply To This Thread
Posting in the Eng-Tips forums is a member-only feature.
Click Here to join Eng-Tips and talk with other members! Already a Member? Login
News
If you are looking for more details, kindly visit Flanged end gate valve.
34
0
0
All Comments (0)
Previous: Universal Flange Adaptor: Your Questions Answered!
Next: 10 Questions You Should Know about Solar Panel Installation
If you are interested in sending in a Guest Blogger Submission,welcome to write for us!
Comments